Abstract
Aim. Compare the dimensional stability of a conventional pouring irreversible hydrocolloid with extended pouring irreversible hydrocolloids. Methodology. Four products with extended emptying indication were evaluated: Jeltrate Plus (Denstply Sirona),
Hydrogum 5 (Zhermack SpA), Algimax (Major), Kromopan (Lascod) and a conventional emptying product (Tropicalgin; Zhermack SpA). For each product, 10 impressions were made and cast in type III plaster at five different storage times (0, 24, 96, 120 and 168 hours). A three-dimensional model scanner was used to digitize the plaster models and make the corresponding measurements: sum of lengths, dimensional variability, percentage of variability. Results. The five commercial brands presented a greater sum of lengths than the control group (p<0,033). At 0, 24 and 96h Tropicalgin and Hydrogum 5 presented significantly less dimensional variation compared to the master model (p<0,001). The variability percentages ranged from 0.24 to 0.91%. Conclusions. Dimensional stability depends on the product used. Stored correctly, the conventionally cast irreversible hydrocolloid appears not to undergo
significant alterations up to 96h, while in the case of Hydrogum 5 it appears to maintain its dimensional stability up to 168h.
References
Rohanian A, Ommati Shabestari G, Zeighami S, Samadi MJ, Shamshiri AR. Effect of storage time of extended-pour and conventional alginate impressions on dimensional accuracy of casts. J Dent (Tehran Univ). 2014;11(6):655–64.
Gümüş HÖ, Dinçel M, Büyük SK, Kılınç Hİ, Bilgin MS, Zortuk M. The effect of pouring time on the dimensional stability of casts made from conventional and extended-pour irreversible hydrocolloids by 3D modelling. J Dent Sci. 2015 Sep;10(3):275–81. DOI: 10.1016/j.jds.2014.05.003
Garrofé AB, Ferrari BA, Picca M, Kaplan AE. Linear Dimensional Stability of Irreversible Hydrocolloid Materials Over Time. Acta Odontol Latinoam. 2015;28(3):258–62.
Vaz da Costa R, Silva Valente M, Soares Da Rocha S. Analysis of the Dimensional Stability of Extended- Storage Irreversible Hydrocolloids. Rev Odontol Bras Cenntral. 2017;26(76):7–10.
Nassar U, Aziz T, Flores-Mir C. Dimensional stability of irreversible hydrocolloid impression materials as a function of pouring time: A systematic review. J Prosthet Dent. 2011 Aug;106(2):126–33. DOI: 10.1016/S0022-3913(11)60108-X
Aalaei S, Ganj-Khanloo R, Gholami F. Effect of Storage Period on Dimensional Stability of Alginplus and Hydrogum 5. J Dent (Tehran). 2017;14(1):31–9.
Todd JA, Oesterle LJ, Newman SM, Shellhart WC. Dimensional changes of extended-pour alginate impression materials. Am J Orthod Dentofac Orthop. 2013 Apr;143(4):S55–63. DOI: 10.1016/j.ajodo.2012.06.016
Imbery TA, Nehring J, Janus C, Moon PC. Accuracy and dimensional stability of extended-pour and conventional alginate impression materials. J Am Dent Assoc. 2010 Jan;141(1):32–9. DOI: 10.14219/ jada.archive.2010.0018
Rodrigues SB, Augusto CR, Leitune VCB, Samuel SMW, Collares FM. Influence of delayed pouring on irreversible hydrocolloid properties. Braz Oral Res. 2012 Oct;26(5):404–9. DOI: 10.1590/S1806-83242012000500005
Choudhary S, Sivakumar I, Buzayan M, Choudhary P. Dimensional accuracy of double poured casts obtained from extended pour alginate impressions: An in vitro study. J Int Oral Heal. 2018;10(6):272. DOI: 10.4103/jioh.jioh_199_18
Cesur M, Omurlu I, Ozer T. Evaluation of digital model accuracy and time-dependent deformation of alginate impressions. Niger J Clin Pract. 2017;20(9):1175. DOI: 10.4103/1119-3077.197012
Luthardt RG, Kühmstedt P, Walter MH. A new method for the computer-aided evaluation of threedimensional changes in gypsum materials. Dent Mater. 2003 Jan;19(1):19–24. DOI: 10.1016/s0109-5641(02)00013-1
Michalakis KX, Asar NV, Kapsampeli V, Magkavali-Trikka P, Pissiotis AL, Hirayama H. Delayed linear dimensional changes of five high strength gypsum products used for the fabrication of definitive casts. J Prosthet Dent. 2012 Sep;108(3):189–95. DOI: 10.1016/S0022-3913(12)60146-2
Sedda M, Casarotto A, Raustia A, Borracchini A. Effect of Storage Time on the Accuracy of Casts Made from Different Irreversible Hydrocolloids. J Contemp Dent Pract. 2008 May;9(4):59–66. DOI: 10.5005/jcdp-9-4-59
CALMON JDQ, RELVAS A, LEFRANÇOIS M, AZEVEDO MV, SOTELO P, SOTELO L. Estabilidade dimensional de moldes obtidos com alginato de armazenamento tardio. Rev Odontol da UNESP. 2019;48. DOI: 10.1590/1807-2577.09819
Hussain MW, Chaturvedi S, Naqash TA, Ahmed AR, Das G, Rana MH, et al. Influence of time, temperature and humidity on the accuracy of alginate impressions. J Ayub Med Coll Abbottabad. 2020;32(Suppl 1(4):S659–67.
BITENCOURT SB, CATANOZE IA, SILVA EVF da, TURCIO KHL, SANTOS DM dos, BRANDINI DA, et al. Extended-pour and conventional alginates: effect of storage time on dimensional accuracy and maintenance of details. Dental Press J Orthod. 2021;26(3):1–28. DOI: 10.1590/2177-6709.26.3.e2119251.oar
Daneu G, Vasconcelos J, Oltramari P, de Almeida M, Guiraldo R, Fernandes T. Dimensional stability of alginate molds scanned at different storage times. Acta Odontológica Latinoam. 2020 Dec;33(3):221–7. DOI: 10.54589/aol.33/3/221
Bang H, Shim H, Cho Y, Park E. Effect of mixing method and storage time on dimensional stability of alginate impressions materials. J Korean Acad Prosthodont. 2020;58(2):86. DOI: 10.4047/jkap.2020.58.2.86
Kusugal P, Chourasiya R, Ruttonji Z, Astagi P, Nayak A, Patil A. Surface detail reproduction and dimensional stability of contemporary irreversible hydrocolloid alternatives after immediate and delayed pouring. Contemp Clin Dent. 2018;9(1):20. DOI: 10.4103/ccd.ccd_676_17
Walker MP, Burckhard J, Mitts DA, Williams KB. Dimensional change over time of extended-storage alginate impression materials. Angle Orthod. 2010 Nov;80(6):1110–5. DOI: 10.2319/031510-150.1
Muhammed B. E-D, Muhammed A. G, Seham A. H. EXTENDED-STORAGE IRREVERSIBLE HYDROCOLLOID IMPRESSION MATERIALS. Alexandria Dent J. 2016 Aug 1;41(2):146–9. DOI: 10.21608/adjalexu.2016.59269
Ghasemi E, Ebadian B, Asadi A, Ghasemi N. Effects of Water/Powder Ratio of Irreversible Hydrocolloid on Dimensional Stability of Impressions. J Islam Dent Assoc IRAN. 2020 Oct 1;32(3):43–9. DOI: 10.30699/jidai.32.3.4.43
Sharif RA, Abdelaziz KM, Alshahrani NM, Almutairi FS, Alaseri MA, Abouzeid HL, et al. The accuracy of gypsum casts obtained from the disinfected extended-pour alginate impressions through prolonged storage times. BMC Oral Health. 2021 Dec 9;21(1):296. DOI: 10.1186/s12903-021-01649-2
Pal A, Singhal MK, Jha D, Chopra M, Yadav K. Environment to Store Alginate at its Best: An In-vitro Study. J Clin DIAGNOSTIC Res. 2023;17(18):20–3. DOI: 10.7860/JCDR/2023/59033.17595
Alcan T, Ceylanoğlu C, Baysal B. The Relationship between Digital Model Accuracy and Time- Dependent Deformation of Alginate Impressions. Angle Orthod. 2009 Jan 1;79(1):30–6. DOI: 10.2319/100307-475.1
Abdelraouf RM. Chemical analysis and microstructure examination of extended-pour alginate impression versus conventional one (characterization of dental extended-pour alginate). Int J Polym Mater Polym Biomater. 2018 Jul 3;67(10):612–8. DOI: 10.1080/00914037.2017.1362636
Potran M, Strbac B, Puskar T, Hadzistevic M, Hodolic J, Trifkovic B. Measurement of the accuracy of dental working casts using a coordinate measuring machine. Vojnosanit Pregl. 2016;73(10):895–903. DOI: 10.2298/VSP150105089P
Pinheiro LOB, Ayala AS, Pomini MC, Cruz VT da, Farias IV del, Samra APB. Linear dimensional stability of irreversible hydrocolloids with and without disinfection at different storage times. RSBO. 2019 Jan 25;15(2):77. DOI: 10.21726/rsbo.v15i2.673
International Organization for Standardization. ISO 21563:2021 - Dentistry — Hydrocolloid impression materials [Internet].
American National Standards Institute. ANSI/ADA Specification No. 19-2003 - Dental Elastomeric Impression Materials [Internet].
Kulkarni MM. Dimensional Changes of Alginate Dental Impression Materials-An Invitro Study. J Clin DIAGNOSTIC Res. 2015;9(8):ZC98–102. DOI: 10.7860/JCDR/2015/13627.6407
Muzaffar D, Braden M, Parker S, Patel MP. The effect of disinfecting solutions on the dimensional stability of dental alginate impression materials. Dent Mater. 2012 Jul;28(7):749–55. DOI: 10.1016/j. dental.2012.03.013
Marquezan M, Jurach EM, Guimarães VD, Valentim RGA, Nojima LI, Nojima M da CG. Does the contact time of alginate with plaster cast influence its properties? Braz Oral Res. 2012 Mar 20;26(3):197–201. DOI: 10.1590/S1806-83242012005000005
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.